UK Power Grid

How well renewables are working, and what gets wasted

Wind now supplies more of Britain's electricity than any other single source, but not all of what it could produce reaches anyone. When the network cannot carry the power, generators are paid to switch off.

Renewables turned down · Last month

1 Aug to 31 Aug 2026. 31 days of published settlement data.

Energy thrown away

484,321MWh

30% lower than the month before

Enough to run about 65,448,838 homes for a day

Paid to switch off

£14,825,455

£30.61 per MWh not generated

Recovered through network charges on bills

Share of wind wasted

9.1%

Of everything wind could have delivered

Average per day

15,623MWh

About £478,241 a day

Which sources were turned down

Wind dominates, but it is not the only renewable that gets curtailed.

Source Curtailed (MWh) Paid Share of curtailment
Wind 411,018.0 £11,159,342 84.9%
Hydro 50,588.3 £2,674,638 10.4%
Biomass 22,715.1 £991,475 4.7%

Who was turned down

Energy curtailed by operator over this period. Scottish wind dominates because the network south of the border cannot carry everything it produces.

View as table
Operator Curtailed (MWh) Share of the period
Moray Offshore Wind East Ltd 117,719.1 24.3%
Seagreen Wind Energy Limited 116,566.0 24.1%
Moray Offshore Wind West Ltd 53,247.3 11.0%
SSE Generation Ltd 44,012.3 9.1%
Viking Energy Wind Farm LLP 36,102.9 7.5%
Drax Power Ltd 22,698.4 4.7%
Marble Power Limited 11,090.4 2.3%
Beatrice Offshore Windfarm Ltd 10,045.6 2.1%
SP Renewables (UK) Limited 8,907.5 1.8%
Neart Na Gaoithe Offshore Wind 5,445.7 1.1%
Limekiln Extension Ltd 4,968.9 1.0%
Clyde Windfarm (Scotland) Ltd 4,369.0 0.9%
South Kyle Wind Farm Limited 3,431.0 0.7%
North Kyle Wind farm Ltd 3,420.0 0.7%
Sonningmay Wind Limited 3,390.9 0.7%
Breesea Limited 2,967.8 0.6%
EDF Energy Customers Limited 2,917.2 0.6%
Soundmark Wind Limited 2,911.2 0.6%
Stronelairg Windfarm Limited 2,534.8 0.5%
Walney Extension Ltd 1,930.9 0.4%
Statkraft Markets Gmbh 1,763.9 0.4%
Creag Riabhach Wind Farm Ltd 1,643.9 0.3%
Sandy Knowe Wind Farm Ltd 1,638.4 0.3%
OnPath Energy Limited 1,463.6 0.3%
Corriegarth Wind Energy LTD 1,339.5 0.3%
AIK2A Sustainable Energy Ltd 1,307.9 0.3%
Erova Energy Limited 1,290.7 0.3%
Fallago Rig Wind Farm Limited 1,233.6 0.3%
Kype Extension Wind Farm Ltd 1,185.8 0.2%
Windy Rig Wind Farm Limited 1,184.0 0.2%
Kennoxhead Wind Farm Limited 1,166.2 0.2%
Eneco Energy Trade 1,151.8 0.2%
Griffin Wind Farm Ltd 1,026.7 0.2%
Uniper UK Limited 1,001.0 0.2%
Twentyshilling Limited 931.2 0.2%
HAGSHAW HILL REPOWERING LTD 840.8 0.2%
Vattenfall Wind Power Ltd 833.5 0.2%
Smartestenergy Limited 788.4 0.2%
Strathy Wind Farm Limited 499.9 0.1%
London Array Limited 476.2 0.1%
Dunmaglass Wind Farm Limited 472.6 0.1%
BROCKLOCH RIG WINDFARM LTD 443.0 0.1%
Evolve Energy Supply Limited 336.3 0.1%
Ormonde Energy Ltd 309.8 0.1%
Benbrack Wind Farm Limited 263.9 0.1%
Morecambe Wind Limited 201.3 0.0%
RWE Renewables UK Robin Rigg 185.5 0.0%
Triton Knoll Offshore Wind 165.0 0.0%
Minnygap Energy Limited 142.6 0.0%
Pen y Cymoedd Wind Farm LTD 122.1 0.0%

How wind is performing right now

Wind output now

10,225MW

Against 28,572 MW of connected capacity

Capacity factor

35.8%

Share of maximum output being delivered

Forecast error

15.6%

859 MW average miss

How far the day-ahead forecast was out

Forecast bias

Cautious

More wind arrived than was forecast

Forecast against outturn

The day-ahead wind forecast and what actually materialised. The forecast runs ahead of the measured line, which stops at the present.

View as table
Half hour Forecast (MW) Actual (MW) Difference
Tue 21:00 2,549 2,019 +530
Tue 22:00 3,077 2,323 +755
Tue 23:00 3,269 2,559 +710
Wed 00:00 3,901 3,121 +780
Wed 01:00 4,327 4,031 +296
Wed 02:00 4,635 4,726 −91
Wed 03:00 5,240 5,288 −48
Wed 04:00 5,390 6,008 −618
Wed 05:00 6,145 8,420 −2,275
Wed 06:00 6,630 8,816 −2,186
Wed 07:00 8,254 8,707 −453
Wed 08:00 8,659 10,225 −1,566
Wed 09:00 9,120 - -
Wed 10:00 9,263 - -
Wed 11:00 9,386 - -
Wed 12:00 9,773 - -
Wed 13:00 9,695 - -
Wed 14:00 9,874 - -
Wed 15:00 10,374 - -
Wed 16:00 10,526 - -
Wed 17:00 10,030 - -
Wed 18:00 9,328 - -
Wed 19:00 8,875 - -
Wed 20:00 8,263 - -
Wed 21:00 7,390 - -
Wed 22:00 6,234 - -
Wed 23:00 5,122 - -
Thu 00:00 4,162 - -
Thu 01:00 3,460 - -
Thu 02:00 2,983 - -
Thu 03:00 2,730 - -
Thu 04:00 2,656 - -
Thu 05:00 2,770 - -
Thu 06:00 3,105 - -
Thu 07:00 3,700 - -
Thu 08:00 4,652 - -
Thu 09:00 5,618 - -
Thu 10:00 6,353 - -
Thu 11:00 7,111 - -
Thu 12:00 7,878 - -
Thu 13:00 8,506 - -
Thu 14:00 9,084 - -
Thu 15:00 9,736 - -
Thu 16:00 10,352 - -
Thu 17:00 10,848 - -
Thu 18:00 11,442 - -
Thu 19:00 12,226 - -
Thu 20:00 13,148 - -
Thu 21:00 14,045 - -
Thu 22:00 14,463 - -
Thu 23:00 14,492 - -
Fri 00:00 14,211 - -
Fri 01:00 13,707 - -
Fri 02:00 12,926 - -
Fri 03:00 12,075 - -
Fri 04:00 11,184 - -
Fri 05:00 10,362 - -
Fri 06:00 9,474 - -
Fri 07:00 8,751 - -
Fri 08:00 8,094 - -
Fri 09:00 7,548 - -
Fri 10:00 7,034 - -
Fri 11:00 6,757 - -
Fri 12:00 6,503 - -
Fri 13:00 6,227 - -
Fri 14:00 6,053 - -
Fri 15:00 5,951 - -
Fri 16:00 5,865 - -
Fri 17:00 5,699 - -
Fri 18:00 5,619 - -
Fri 19:00 6,060 - -
Fri 20:00 6,686 - -
Fri 21:00 7,305 - -
What curtailment is, and why it happens

Britain's windiest places and its biggest demand are at opposite ends of the country. Scotland generates far more wind power than it uses, and the transmission lines running south can only carry so much. When more is produced than the network can move, something has to give.

What gives is the generator. The system operator accepts a bid from it to produce less, and pays it to stop. The energy is not stored or redirected anywhere - it simply never gets produced, and the wind passes through the turbines unused. Gas plants nearer the demand are then paid to make up the shortfall, so consumers pay twice.

This is a network problem rather than a wind problem. New transmission links and grid-scale storage are being built to relieve it, but they take years, while wind capacity has grown quickly. Curtailment is the visible cost of that mismatch.

Forecast error matters for a related reason. Wind being variable is manageable; wind being unpredictable is expensive, because the system operator has to hold other plant in reserve to cover whatever the forecast gets wrong. A smaller error means less standby generation burning fuel for nothing.

Why solar is not shown here

Solar curtailment cannot be reported from this data, and it would be misleading to show a zero. Almost all of Britain's solar is connected to local distribution networks rather than the transmission system, so it never enters the Balancing Mechanism - the market through which generators are instructed and paid to change output.

There is no solar fuel type in the Balancing Mechanism unit register at all. A handful of very large solar farms are registered under a general category, but they are a small fraction of installed solar and are not identifiable as solar with any confidence.

Wind, hydro and biomass are all shown above, because those do appear in the register and are all curtailed in practice. Solar is the one renewable this data cannot speak to.

Updated at 09:04. This page keeps itself current.